e-STUDIO550/650/810 ERROR CODES AND SELF-DIAGNOSIS
2 - 18
JUNE 2002 © TOSHIBA TEC
248
Developer bias +DC ON/OFF (Operation is possible without the developer unit.)
3
249
Developer bias -DC1 ON/OFF (Operation is possible without the developer unit.)
3
250
Developer bias -DC2 ON/OFF (Operation is possible without the developer unit.)
3
251
Developer bias -DC3 ON/OFF (Operation is possible without the developer unit.)
3
252
Main charger ON/OFF (Operation is possible without the developer unit.)
3
254
Duct in fan ON/OFF
3
255
Transfer belt cleaning brush bias ON/OFF (Operation is possible without the developer unit.)
3
257
Duct out fan (high speed) ON/OFF
3
258
Duct out fan (low speed) ON/OFF
3
259
Heater fan (high speed) ON/OFF
3
260
Heater fan (low speed) ON/OFF
3
261
Scanner motor ON (automatically stopping at the limit position, speed changeable by the ZOOM keys)
2
264
SLG fan ON/OFF
3
267
Exposure lamp ON/OFF
3
270
Tandem LCF tray motor ON (tray lifted)
2
271
External LCF tray motor ON (tray lifted)
2
272
External LCF feed clutch ON/OFF
3
273
External LCF transport clutch ON/OFF
3
274
Gate solenoid ON/OFF
3
276
Cassette tray-up motor 1 ON (1st cassette tray lifted)
2
278
Cassette tray-up motor 1 ON (2nd cassettetray lifted)
2
279
Cassette tray-up motor 2 ON (3rd cassettetray lifted)
2
280
Cassette tray-up motor 2 ON (4th cassettetray lifted)
2
283
RADF large original exit roller (forward rotation) ON/OFF
3
284
RADF large original exit roller (reverse rotation) ON/OFF
3
285
RADF small original exit roller (forward rotation) ON/OFF
3
286
RADF small original exit roller (reverse rotation) ON/OFF
3
287
RADF large original exit solenoid ON/OFF
3
288
RADF small original exit solenoid ON/OFF
3
289
RADF disengagement solenoid ON/OFF
3
290
RADF tray lift motor ON (tray lifted)
2
292
Laser unit fan (high speed) ON/OFF
3
293
Laser unit fan (low speed) ON/OFF
3
295
Power OFF mode
4
450
IH fan (high speed) ON/OFF
3
451
IH fan (low speed) ON/OFF
3
452
Reverse section fan 1 (high speed) ON/OFF
3
453
Reverse section fan 1 and 2 (low speed) ON/OFF
3
454
Reverse section fan 2 (high speed) ON/OFF
3
Code
Function
Procedure