e-STUDIO550/650/810 ADJUSTMENT
3 - 40
June 2002 © TOSHIBA TEC
3. 11. 2. Skew adjustment
When an image skew occurs, carry out copying at the manually placed original mode and check it is not
occuring. When it occurs at this mode, adjust the scanning section (
Chap.3.3.4).
(1) Check if the RADF unit is installed properly (
Chap.3.11.1).
(2) Adjust the image according to the following steps while checking the conditon of the image skew.
쩺
쩻
Step 2
Loosen the screws fixing the hinges at the rear
side (1 screw each for the feed and exit sies) and
perform the adjustment by turning the adjustment
screw from the front side.
In case of : Turn the adjustment screw to CCW
direction.
In case of : Turn the adjustment screw to CW
direction.
Step 1
Open the jam access cover and adjust the position of the plate at the registration roller side.
In case of : Move a screw to the long hole and shift the plate to the direction of B.
In case of : Move a screw to the long hole and shift the plate to the direction of A.
쩸
쩹
Step 3
Open the jam access cover and adjust the position of the plate at the read roller side.
In case of : Move a screw to the long hole and shift the plate to the direction of B.
In case of : Move a screw to the long hole and shift the plate to the direction of A.
쩼
쩽
Step 1
Step 3
A
A
B
B
[Feed side]
Adjustment screw
Step 1
Step 2
Step 3
쩸
쩹
쩺
쩻
쩼
쩽
Paper
Paper
Paper
Image
Image
Image