e-STUDIO550/650/810 TROUBLESHOOTING
5 - 118
JUNE 2002 © TOSHIBA TEC
Defective area
Step
Check Items
Prescription
Cassette
LCF
PFP
Feed roller
Rollers
Aligning amount
Registration roller
Pre-registration guide
1
Is the cassette or LCF/PFP properly installed?
2
Is there too much paper in the cassette
or LCF/PFP?
3
Is the corner of the paper folded?
4
Are the side guides of the cassette or LCF
/PFP properly installed?
5
Is the surface of the feed roller dirty?
6
Are the roller and shaft secured?
7
Is the aligning amount proper?
8
Is the spring detached from the registra-
tion roller?
9
Is the pre-registration guide properly
installed?
Install the cassette or LCF/PFP properly.
The hieght of the paper stack should not exceed
55mm. (137mm or lower/room for LCF)
Change the direction of the paper and set it again.
Adjust the position of the side guides.
Clean the roller surface with alcohol, or replace the
roller.
Check and fasten the E-rings, pins, clips and
setscrews.
Increase the aligning amount.
Attach the spring correctly. Clean the roller if it is
dirty.
Correct it.
(11) Skew (inclined image)