Defective area
Step
Check Items
Prescription
Remarks
Cleaning blade
12 Is the blade in proper contact with the drum?
Check the blade.
13 Has the cleaning blade been turned
Replace the blade.
up?
Check and replace the drum
if necessary.
Toner recovery auger
14 Is the toner recovered normally?
Clean the toner recovery auger.
Check the pressure of the cleaning blade.
Recycle unit
15 Is the recycle unit installed properly?
Check and correct the installation.
16 Is the recycle toner transport
Check if the connector comes off.
motor performed?
Replace the motor if necessary.
17 Is the hopper motor performed?