e-STUDIO550/650/810 TROUBLESHOOTING
5 - 120
JUNE 2002 © TOSHIBA TEC
Defective area
Step
Check Items
Prescription
Main charger wire
Fuser roller, separation
finger and thermistor
Cleaning roller for
pressure roller
High-voltage transformer
(main charger)
Drum
Scanner carriage
1
Is the charger wire dirty or deformed?
2
Are the fuser roller, separation finger and
thermistor dirty?
3
Has the cleaning roller for the pressure
roller reached its PM life?
4
Is the output from the high-voltage trans-
former normal?
5
Is there a deep scratch on the drum sur-
face?
6
Are there thin scratches (drum pitting) on
the drum surface?
7
Is there a foreign object on the carriage
rail?
Clean or replace the charger wire.
Clean them.
Replace it.
Check the circuit and replace the high-voltage
transformer if it is defective.
Replace the drum if the scratch has reached the
aluminum base.
Check and adjust the contact condition of the
cleaning blade and recovery blade.
Remove the foreign object.
(13) Black banding (at right angle with the feeding direction)
Feeding direction