e-STUDIO550/650/810 ADJUSTMENT
3 - 16
June 2002 © TOSHIBA TEC
(e) Image position adjustment of the secondary scanning direction (Deviation adjustment of the scanner
secondary scanning start position)
1. Turn ON the power while the digital keys [0] and [5] are pressed simultaneously.
(Adjustment
mode)
2. Select the value of the top margin to “0”.
(Adjustment mode)
(Enter the code [430] with the digital keys)
[START]
(Enter the value “0”
with the digital keys)
Press the [SET] or [INTERRUPT] key to store the value in the RAM.
3. Place a ruler on the original glass with its leading edge pushed against the original scale on the left.
4. Select the condition of 2nd cassette (A3/LD) and 400%, enter “305” with the digital keys, and press
the [START]
[SET] or [INTERRUPT]
[COPY] key to make a copy.
5. Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
6. Check if the distance D is within the range of 34±0.5 mm.
7. If not, change the value taking the following procedure, and repeat the steps 3 to 5 until the distance
falls within range.
<Procedure>
(Adjustment mode)
(Enter the code [305] with the digital keys)
[START]
(Enter a value (acceptable values : 0 to 255) with the digital keys)
Press the [SET] or the [INTERRUPT] key to store the value in the RAM.
(“100% A” is displayed.)
* The larger the adjustment value, the more the image is shifted to the leading edge
(0.1433 mm/step).
10
20
30
40
D
Copied image of the ruler
Feeding direction