36
y
The Pre Alarm will allow user to check, during playback, the previously recorded video before the record start time.
y
Each frame on Title column shows camera title registered in DEVICES>Camera/PTZ. User cannot change camera titles
here.
y
Click (
) each frame on Resolution column to select recording resolution of a corresponding camera. User may select one
of 720x480, 720x240 and 360x240.
y
Click (
) each frame on Frames column to select recording rate of a corresponding camera. Recording rate varies by
camera. Below lists the maximum recording rate of each camera.
NTSC(PAL) 360x240
720x240
720x480
4 Channel DVR
120(100)
120(100)
60(50)
8 Channel DVR
240(200)
120(100)
60(50)
16 Channel DVR
480(400)
240(200)
120(100)
y
Click (
) each frame on Quality column to select recording quality of a corresponding camera. User may select one of
Super, High and Std.
y
Click (
) each frame on Duration column to select recording duration (i.e., 1 second ~ 3 hours) of a corresponding camera.
y
Choose ‘OK’ to confirm the setting.
4.5.4 Motion
Detection
y
Please click (
) RECORD>Motion Detection and the following screen will appear.
y
The Motion Detection menu will allow user to set Motion detection alarm.
y
Press SETUP key (or right mouse button) and the SETUP menu will appear.
y
SETUP menu descriptions.
-
Camera: select camera for setup.
-
Sensitivity: select sensitivity (Low, Normal and High)
-
Reverse Vert: activate the entire column at the cursor’s position.
-
Reverse Horz: activate the entire row at the cursor’s position.
-
Select All: active all blocks.
-
Deselect All: deactivate all blocks.
-
Copy to All Cameras: The present channel setup applies to all other cameras. Only when click save button, the changed
setup can be saved.
-
Save: save the new settings and go back to previous menu (page).
-