It is strongly recommended that an initial check out be performed
on the motor-drive combination at this time. This should be done
with the motor disconnected from the load. This procedure will
verify that the correct motor is chosen and that it is connected and
phased properly before proceeding further.
Setup / Configuration Screen
In order to access the Setup / Configuration screen to perform your
initial checkout, please follow the steps below:
1. Recheck power, motor and encoder connections to make sure all are
correct.
2. Apply power to the Axiom Plus. If the unit has NOT yet been
configured, it should flash an “F-99” fault code. If it HAS been
configured, it should display the letter “d” on the status indicator.
3. Open the Tol-O-Motion Axiom setup software. The Tol-O-Motion
setup software main menu will appear (see Figure 8.1).
Figure 8.1 - Tol-O-Motion Axiom Plus Setup Software Opening Screen
4. Connect the serial communications cable from a spare serial port on
your computer to the COMM connection (9-pin D-sub connector)
on the drive.
8 - 1
Initial Check Out