WARNING!
Large leakage currents exist in AC line filters. They must
be grounded properly before applying power. Filter capacitors retain
high voltages after power removal. Before handling the equipment,
voltages should be measured to determine safe levels prior to
handling the equipment. Failure to observe this precaution could
result in severe bodily injury.
WARNING!
The circuits in the Axiom Plus are potential sources of
severe electrical shock. Follow all safety guidelines to avoid shock.
WARNING!
Rotating motor shafts can cause extensive damage and
injury. Motors must be properly guarded during testing and in the
final installation.
WARNING!
The user must provide an external, hard-wired
emergency stop circuit in addition to the controller circuitry. This
circuit must remove power from the system in case of improper
operation. The drive enable is not adequate for this purpose, as it
does not remove supply voltage from the unit and may not disable
the system in all circumstances. Uncontrolled machine operation
may result if this procedure is not followed. Failure to observe this
precaution could result in severe bodily injury.
WARNING!
High voltage may be present on the terminals of the
unit. Remove power and disconnect the power cable before making
or removing any connection. Again mention wait for bus bleed-
down.
Caution Notices
Caution!
Do not tin (solder) the exposed leads on cables. Tinned
leads will loosen in time and may come loose from their screw
terminal connections.
Caution!
Ensure that encoder signals are connected properly.
Incorrect connection of encoder signals will result in a “run away”
motor condition and/or incorrect commutation.
Caution!
Electronic components are subject to damage by static
electricity. Follow Electrostatic Discharge (ESD) practices while
handling components.
!
!
!