For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com
Figure 9.16 - Axiom Plus Sinking Output Connected to Sourcing Input Using Internal
Power Supply
Figure 9.17 - Axiom Plus Sinking Output Connected to Sourcing Input Using External
Power Supply
0 VDC
+ VDC
Neutral
Line
+24 Vdc
24Vdc RTN
OUT +
OUT -
OUT +
OUT -
IN
IN
IN
IN
IN
IN
IN
VDC COM
IN
Sinking Output
AxiomPlus
Sourcing
Input PLC
5 - 24 VDC
Power Supply
IN
IN
IN
IN
IN
IN
IN
VDC
IN
24Vdc RTN
OUT -
OUT +
OUT -
OUT +
+24 Vdc
Sinking Output
AxiomPlus
Sourcing Input
Motion Controller
or PLC
9 - 11
I / O C O N N E C T I O N S : 9