Technical data
EF200F-C
154
Supply voltage for a compact version without a local display
1)
"Output; input"
Minimum
terminal voltage
2)
Maximum
terminal voltage
4-20 mA HART, pulse/frequency/
switch output
侒 DC 12 V
DC 35 V
1)
In event of external supply voltage of the power supply unit with load
2)
The minimum terminal voltage increases if local operation is used: see the following table
3)
Voltage drop 2.2 to 3 V for 3.59 to 22 mA
Increase in minimum terminal voltage
Order code for "Display; operation"
Increase in minimum
terminal voltage
Local operation
+ DC 1 V
Order code for "Sensor version; DSC sensor; measuring tube"
Increase in minimum
terminal voltage
Mass steam; 316L; 316L (integrated pressure/temperature measurement)
+ DC 1 V
Power consumption
Transmitter
"Output; input"
Maximum power consumption
4-20 mA HART, pulse/frequency/
switch output
• Operation with output 1: 770 mW
• Operation with output 1 and 2: 2770 mW