EF200F-C
Commissioning
83
Parameter
Prerequisite
Description
Selection / User
entry
Factory setting
Switch-off delay
• The Switch option is
selected in the Operating
mode parameter.
• The Limit option is selected
in the Switch output
function parameter.
Define delay for the switch-off
of status output.
0.0 to 100.0 s
0.0 s
Failure mode
‒
Define output behavior in
alarm condition.
• Actual status
• Open
• Closed
Open
Invert output signal **
‒
Invert the output signal.
• No
• Yes
No
*
Visibility depends on order options or device settings
10.4.7 Configuring the local display
The Display wizard guides you systematically through all the parameters that can
configured for configuring the local display.
Navigation
"Setup" menu → Display
Display
Format display
Value 1 display
0% bargraph value 1
100% bargraph value 1
Value 2 display
Value 3 display
0% bargraph value 3
100% bargraph value 3
Value 4 display
**
Switch output isnʼt inverted when “Open” or “Close” is selected for the Failure mode option
►