THOR-SSM
88
Rev. : 02/09/2012
Control commands
In Single-head KVM- Switch operating mode, the following control commands are allowed:
•
STX, 0x40, 0x80, ETX
Acknowledgement of the system info
•
STX, 0x45, ETX
Reset on factory settings
•
STX, 0x54, ETX
Reset the Crosspoint- Switch
•
STX, 0x4F, 0x81, < Loc-No>, ETX
S
witch (local-)input to (remote-)output, the
existing connection is disconnected at the
same time
where:
< Loc-No>
7Bit date 1 to 7
Examples:
STX, 0x54, ETX
Reset the switch and set the connections as a function of
SW7 (see above)
STX, 0x40, 0x80, ETX
Read the system info (version number) from the switch
STX, 0x4F, 0x81, 0x84, ETX
Switch console (Remote Unit) to (Local Unit) CPU 4
STX, 0x4F, 0x81, 0x85, ETX
Switch console (Remote Unit) to (Local Unit) CPU 5
(existing connection to CPU 4 is disconnected)
STX, 0x54, ETX
Reset the switch and set the connections as a function of
SW7 (see above)