APPENDIX E: PROTOCOL FOR COMMAND MODE
Rev. : 02/09/2012
133
Switching functions
Glossary:
INPUT
= Input
= to a Local Unit
=CPU
OUTPUT
= Output
= to a Remote Unit
=WS
(= Workstation = KVM
= Console)
The INPUT- numbers are valid (depends on operating mode) in the range of 1..7
The OUTPUT- numbers are valid (depends on operating mode) in the range of 1..7
The INPUT- and OUTPUT- numbers are to encrypt in 7bit-data
Commands, switching functions
No
Function
Command
Answer
1
switch an OUTPUT
to an INPUT
STX, 0x47, <OUTPUT -No>,,
<INPUT -No>ETX
ACK
2
switch off a single
OUTPUT
STX, 0x48, < OUTPUT -No>, ETX ACK
3
switch a single
OUTPUT feedback
channel to INPUT
STX, 0x4B, < INPUT -No>, <
OUTPUT -No>, ETX
ACK
4
switch off a single
OUTPUT feedback
channel
STX, 0x4C, < INPUT -No>, ETX
ACK
5
switch single bi-
directional INPUT –
OUTPUT-connection
STX, 0x4F, < OUTPUT -No>, <
INPUT -No>, ETX
ACK
6
switch off single
bidirectional INPUT-
OUTPUT-connection
STX, 0x50, < OUTPUT -No>, ETX ACK
7
switch off all INPUT-
OUTPUT-
connections
STX, 0x52, ETX
ACK
8
save switching status
to macro
STX, 0x66, 0x80, <1Byte, 7-Bit-
Makro-No>, ETX
ACK
9
load switching status
from m
acro
STX, 0x67, 0x80, <1Byte, 7-Bit-
Makro-No>, ETX
ACK