![THOR TH-SSM Instruction Manual Download Page 139](http://html1.mh-extra.com/html/thor/th-ssm/th-ssm_instruction-manual_1110446139.webp)
APPENDIX H: SPECIFICATIONS
Rev. : 02/09/2012
139
B
THOR Small Switch Unit
Power Supply
Voltage
AC: 90-240VAC-0.5A-47-63Hz
DC: 5VDC-2000 mA
Power required
5V/2000mA
Interface
RJ45
1000 Mbit High-speed transmission.
Wiring acc. EIA/TIA 568B Gigabit Ethernet
LC (fiber)
1000 Mbit High-speed transmission.
Gigabit Ethernet
RJ45 – Serial (switching
connector):
115.2 KBAUD, 8 bit data, 1 Stop, NO parity
Software Handshake only (XON/XOFF)
Maximum Length of Interconnection Cable
CATx installation cable
140m (400ft) -
AWG24 (solid cable)
CATx patch cable
70m (200ft) -
AWG26/8 (stranded cable)
Type of Interconnection Cable
CATx installation cable AWG24
(solid cable)
S/UTP (Cat5) cable acc. EIA/TIA 56A, TSB 36 or
Digital STP 17-03170. Four pairs AWG 24. Wiring
acc. EIA/TIA 568A (1000BaseT).
CATx patch cable AWG26/8
(stranded cable)
S/UTP (Cat5) cable acc. EIA/TIA 56A, TSB 36 or
Digital STP 17-03170. Four pairs AWG 26/8. Wiring
acc. EIA/TIA 568A (1000BaseT).
Maximum Length of Interconnection Cable (Fiber - LC Connectors)
Singlemode 9
µ
m
10.000m (32, 750ft)
Multimode 50
µ
m
400m (1, 300ft)
Multimode 62.5
µ
m
200m (650ft)