12.3 TROUBLESHOOTING CAUSE-SOLUTION
PROBLEM
CAUSE
REMOVAL OF THE CAUSE
PELLET TANK IS EMPTY
(DISPLAY SHOWS THE
INSCRIPTION “AL PE”)
EMPTY THE BURNER AND CLEAN IT
UP
FILL UP THE TANK WITH PELLETS
FEEDER SCREW BLOCKED BY
FOREIGN OBJECT SUCH AS
NAIL, NYLON, PIECE OF WOOD
REMOVE THE FOREIGN BODY
INSIDE THE TANK.
(DISPLAY SHOWS THE
INSCRIPTION “AL PE”)
CUT OFF THE POWER AND
REMOVE THE FOREIGN OBJECT.
SMOKE EXHAUST NOT FREE, OR
WITH TERMINAL THAT
OBSTRUCTS THE PASSAGE OF
SMOKE
(DISPLAY SHOWS THE
INSCRIPTION “AL OP”)
EMPTY THE BURNER AND CLEAN IT
UP
CHECK THE SMOKE EXHAUST AS IT
COULD BE CLOGGED
OUTLET TERMINAL CLOGGED
BECAUSE A GRILL OR
TERMINAL HAS BEEN INSERTED
WHICH PREVENTS THE FREE
PASSAGE OF SMOKE
(DISPLAY SHOWS THE
INSCRIPTION “AL OP”)
EMPTY THE BURNER AND CLEAN IT
UP
CHECK THE SMOKE OUTLET AND
REMOVE THE GRILL OR TERMINAL
GUST OF WIND WHICH HAS
MADE THE APPLIANCE GO
INTO SAFETY MODE
(DISPLAY SHOWS THE
INSCRIPTION “AL OP”)
EMPTY THE BURNER AND CLEAN IT
UP
SWITCH THE POWER SUPPLY TO
THE APPLIANCE OFF THEN BACK
ON AGAIN
PELLETS DO NOT DROP INTO
THE BURNER
THE PELLET SCREW MOTOR
DOES NOT WORK
REPLACE THE PELLET SCREW
MOTOR