THE RESET THERMOSTAT
TRIPPED
(DISPLAY SHOWS THE
INSCRIPTION “AL T max” )
THE ROOM FAN IS BROKEN AND
MUST BE REPLACED. REPLACE THE
FAN AND REACTIVATE THE
THERMOSTAT BEHIND THE
AAPPLIANCE
DELAYED START BECAUSE THE
SCREW FEEDER WAS EMPTY
(DISPLAY SHOWS THE INSCRIPTION “AL AC”)
EMPTY THE BURNER AND CLEAN IT UP
FILL UP THE TANK WITH PELLETS
THE APPLIANCE SHUTS OFF
A FEW MINUTES
AFTER THE END OF
THE START UP CYCLE
BURNER IS DIRTY. VERY
DELAYED START
(DISPLAY SHOWS THE INSCRIPTION “AL AC”)
EMPTY THE BURNER AND CLEAN IT AS INDICATED IN THIS MANUAL
SMOKE OUTLET BLOCKED OR
TERMINAL OBSTRUCTING THE
SMOKE PASSAGE
EMPTY THE BURNER AND CLEAN IT UP
CHECK THE SMOKE OUTLET AND REMOVE THE GRILL OR TERMINAL
BURNER IS DIRTY
EMPTY THE BURNER AND CLEAN IT AS INDICATED IN THIS MANUAL
PELLETS WITH DEPOSIT ABOVE
PERMISSBILE LIMITS
EMPTY THE BURNER AND CLEAN IT AS INDICATED IN THIS MANUAL
SET THE OPERATING PROGRAM “P2”
THE APPLIANCE ACCUMULATES
PELLETS IN THE BRAZIER
DURING THE
STANDARD OPERATION
THE BURNER IS NOT PROPERLY
PLACED ON ITS SEAT
EMPTY THE BURNER AND CLEAN IT
AS INDICATED IN THIS MANUAL
REPOSITION THE BURNER CORRECTLY IN ITS LODGING
THE APPLIANCE DOES NOT
START UP
THE SPARK PLUG IS DAMAGED
(DISPLAY SHOWS THE
INSCRIPTION “AL AC”)
EMPTY THE BURNER AND CLEAN IT
AS INDICATED IN THIS MANUAL
REPLACE THE SPARK PLUG
THE APPLIANCE
ACCUMULATES PELLETS IN THE
BRAZIER
CLEAN THE GLASS MORE OFTEN
CLEAN AND SERVICE THE HEATER
SET THE OPERATING PROGRAM
“P2”
THE GLASS IS COVERED
IN BLACK SOOT
BRAZIER BLADE POSITIONED
INCORRECTLY OR WORN OR
MISSING
POSITION THE BRAZIER BLADE
CORRECTLY OR INSTALL IT