Pg. 8
2.2 MODEL 2000
2000
Height (mm)
928
Depth (mm)
469
Length (mm)
418
Weight (Kg)
103
Maximum power at firebox (kW)
2.9/7.45
Rated power min./max. (kW)
2.5/6.39
Min/max consumption (Kg/h)
0.60/1.54
Ø smoke exhaust pipe (mm)
80
Min. draught at rated power (Pa)
12
Min. draught at reduced power (Pa)
10
Tank capacity (Kg)
approx. 14
Average smoke temperature at rated power (°C)
184
Average smoke temperature at reduced power (°C)
102 .9
Smoke flow at rated power (g/sec)
6
Smoke flow at reduced power (g/ sec)
4.5
Efficiency at rated power (%)
85.8
Efficiency at reduced power (%)
86.26
CO concentration in exhaust gas with 13% O2 at rated
power (mg/M3)
94.1
CO concentration in exhaust gas with 13% O2 at rated
power (mg/M3)
314.2
Power supply voltage and frequency
220 V 50 HZ
Max electrical consumption
1.18 A – 271 W
Min electrical consumption
0.29 A – 66 W
Room heating capacity cubic metres
189**
* All the data are based on the heater fuelled with Austrian standard ÖNORM M 7135 type-approved pellets.
** It is important to take into consideration the fact that the heatable volume is greatly influenced by the insulation of the
house (energy class of the building) and by the position of the appliance in the planimetry of the house, therefore the
indicated values may vary, even significantly.
3 – GENERAL DESCRIPTION
3.1 OPERATING TECHNOLOGY
Your heater has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions
managed with microprocessor technology guarantee high reliability and optimal performance.
3.2 THE PELLET
The heater is fuelled by pellets, that is, cylinders of compressed sawdust; this allows you to fully enjoy the heat of the flame without
having to manually stoke the combustion.
The pellets have a 6 mm diameter and a maximum length of 15 mm. They have a maximum moisture content of 8%; thermal value
4000/4500 Kcal/Kg and density of approx. 620-630 Kg/m³.
It is strictly forbidden to use any pellet type other than that specified above. The use of fuel that does not comply with the
above specifications not only immediately invalidates the warranty for the appliance but can also create dangerous
situations. Do not use the appliance as an incinerator, at the risk of voiding the warranty.
3.3 THE FEEDBOX
The feedbox is situated in the top part of the appliance. The load capacity specified in the technical data can vary
according to the specific weight of the pellets.
Take special care when loading the tank as the screw feeder at its base is in motion. Take care when topping up with
fuel as the loading area can get very hot.
Only pellets that comply with the specifications listed above must be fed into the tank; never insert foreign objects into
the tank.
Attention: when loading the pellets into the tank take care not to drop any in the inner parts of the appliance, as this
could cause live flames inside the appliance.
The manufacturer recommends emptying the tank and vacuuming the screw feeder zone once a month and during
the summer period. The appliance is designed to run on pellet fuel. Use of other combustible materials in the tank
and/or combustion chamber is strictly prohibited.
9
2
8
418
4
6
9
9
2
8
454
1
9
8
O
80
139