Pg. 13
• By holding down button (4) and pressing button (3) repeatedly the level changes in the following sequence: P2... ...P0 ... P1.
If the change is made while the appliance is running the difference in the flame will be apparent in a few seconds.
• For the entire procedure to be confirmed and to move back to the heater status display, key (6) must be repeatedly pressed until
the operating status is displayed.
It is mandatory to pay particular care when selecting the most appropriate operating cycle for your installation. After
the selection of the operating cycle a thorough cleaning of the brazier is mandatory. Caution: the pellet consumption
value is not affected by the operating level settings.
6 – USE OF THE APPLIANCE
6.1 SWITCHING ON THE HEATER
Before starting the heater verify that all the components are positioned correctly: ash pan, brazier, firebox back and inspection caps.
Remove the adhesive stickers from the glass in order to prevent leaving permanent combustion residues caused by combustion of
the stickers themselves.
Connect the feed cable and turn the switch installed on the back of the appliance to position "1" (= ON). Fill the pellet tank.
To turn the heater on it is necessary for the inscription OFF to be present on the display: if it is not present, the key (6) must be
repeatedly pressed until the inscription OFF appears.
• Press button (1) to start the lighting process.
• When key (1) is repeatedly pressed, the desired combustion level can be set and it will only be active at the end of the ignition
stage (20 minutes).
• Pressing button (2) repeatedly will set the six speeds, which correspond to the six LEDs on the fan display, which will only become
active once the thermostat has closed at 42°C.
CAUTION During the first lighting and every time the appliance is restarted after it has run out of pellets and shut
down, the appliance may fail to light. This is due to the fact that the screw feeder is completely empty. In this case it is
necessary to start the lighting procedure all over again. Check that the brazier is in the correct position.
The lighting process (Star on the display) lasts 20 minutes. During this time the heater ignores all the ventilation and
combustions settings. The fan starts as soon as the temperature of the heater body exceeds 42°C. After the 20
minutes have elapsed the word ON appears on the display.
6.2 COMBUSTION AND VENTILATION ADJUSTMENTS
Set the heating value of the heater by acting on button (1) or on the supplied remote control. The heating value regulates the
quantity of pellets fed into the firebox. When all five LEDs are lit the combustion power is at the maximum level.
To set the ventilation speed press button (2) or use the supplied remote control. The ventilation speed regulates the
number of fan revolutions. When all six LEDs are lit the fan is running at maximum speed.
A slight vibration of the heater is quite normal when it is running.
6.3 INFRARED REMOTE CONTROL
A practical infrared remote control is supplied with the heater: adjust the ventilation level by means of the left button, whereas use
the right button to start the heater, to adjust the power and combustion level and to switch off the appliance.
7 – ROOM TEMPERATURE THERMOSTAT / CHRONOTHERMOSTAT (not supplied)
The appliance is fitted out for and programmed for “piloting” by a room temperature thermostat or by a
chronothermostat, neither of which are supplied with the heater.
The power board contacts are "DRY", consequently they never require energising! If the contacts are powered with
a voltage greater than 6 V this will result in damage to the electronic board and consequently the immediate
voiding of the WARRANTY. The services of a specialist are required to assemble the accessories.