ROOM TOO BIG AND/OR
WALLS TOO COLD
SEPARATE THE SPACES
THE HEATER SHOULD OPERATE
FOR MORE TIME AND WITH
MORE POWER
POOR PELLETS
REPLACE THE PELLETS WITH A
BRAND THAT IS CERTIFIED IN
ACCORDANCE WITH
STANDARD OM 7135
CEILINGS TOO HIGH
AND/OR PRESENCE OF
STAIRS THAT DISPERSE THE
HEAT ELSEWHERE.
SEPARATE THE SPACES
THE HEATER SHOULD OPERATE
FOR MORE TIME AND WITH
MORE POWER
THE HEATER DOES NOT SEEM
TO HEAT
ROOM TEMPERATURE
THERMOSTAT IS SET TOO
LOW
SET A HIGHER TEMPERATURE
THE APPLIANCE IS SWITCHED OFF BUT
THERE ARE STILL UNBURNT PELLETS
IN THE BRAZIER
PELLET TANK IS EMPTY
(DISPLAY SHOWS THE
INSCRIPTION “AL PE”)
EMPTY THE BURNER AND
CLEAN IT UP
FILL UP THE TANK WITH PELLETS
THE APPLIANCE SHUTS OFF
25 MINUTES AFTER THE
START UP CYCLE
THE 42°C THERMOSTAT IS
BROKEN OR FAULTY
REPLACE THE 42°C
THERMOSTAT
THE SLIDING COVER (MODEL 2000)
IS HARD TO MOVE
PELLETS IN THE COVER
GUIDES
USE A VACUUM CLEANER TO
REMOVE THE PELLETS FROM
THE GUIDES
THE PROGRAMMING AND TIME
DO NOT REMAIN
THE BUFFER BATTERY IN THE
CONTROL PANEL IS
EXHAUSTED
REPLACE THE BATTERY
(SEE PARAGRAPH 8.4)