CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 

is known to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de 

carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et 

des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de 

renseignements, veuillez consulter le site www.P65warnings.ca.gov

Certified to: UL 1482-2011 (R2015) and 

ULC-S627-00 (R2016)

Mobile home approved (U.S. ONLY)

U.S. Environmental Protection Agency 

Certified to comply with 2020 particulate 

emissions standards.

R

Report Number: F19-476

SAFETY NOTICE:

If this heater is not properly installed, a house fire may result. 

For  your  safety,  follow  the  installation  instructions.  Never 

use make-shift compromises during the installation of this 

heater. Contact local building or fire officials about permits, 

restrictions and installation requirements in your area.

CAUTION!

Please read this entire manual before you install or use your 

new room heater. Failure to follow instructions may result in 

property damage, bodily injury, or even death. Improper 

Installation Could Void Your Warranty!

Save  these  instructions.  This  manual  will  help  you  to  obtain 

efficient, dependable service from the heater, and enable 

you to order repair parts correctly. Keep in a safe place for 

future reference.

Summary of Contents for AW2020E

Page 1: ... UL 1482 2011 R2015 and ULC S627 00 R2016 Mobile home approved U S ONLY U S Environmental Protection Agency Certified to comply with 2020 particulate emissions standards R Report Number F19 476 SAFETY NOTICE If this heater is not properly installed a house fire may result For your safety follow the installation instructions Never use make shift compromises during the installation of this heater Co...

Page 2: ...e Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7 m Maximum Log Length 21 533 5 mm Dimensions Overall Depth x Width x Height AW2020E BL 21 x 27 x 31 4 534 mm x 686 mm x 798 mm AW2020E BP 21 x 29 4 x 31 25 534 mm x 737 mm x 794 mm Combustion Chamber Width x Depth 22 3 4 X 11 78 578 mm X 300 mm Volume Cubic Feet 1 6 cubic feet Door Openin...

Page 3: ... 2 bolts 3 washers and 3 weld tabs provided in the parts box FIREBRICK CONFIGURATION Replace the Firebrick as shown in the illustration 5 16 18 x 1 1 2 BOLT WASHER HEATER TOP GASKET WELD TAB Assembly Instructions TOOLS AND MATERIALS NEEDED FOR INSTALLATION You will need a drill with a 1 8 bit to install sheet metal screws into connector pipe A 5 16 socket wrench or screw driver to install the room...

Page 4: ... LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS HEATER KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE IN THE EVENT OF A CHIMNEY FIRE PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN CALL THE FIRE DEPARTMENT DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE ...

Page 5: ...D 29 29 737 737 E 12 12 305 305 F 22 22 559 559 D B A C E F E OUTSIDE COMBUSTION AIR Your wood stove is approved to be installed with an outside air intake 4FAK which is necessary for a mobile home This type of installation is also required in air tight houses and houses with negative pressure problems You can purchase this option through your heater dealer Make sure to specify the part number men...

Page 6: ... MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME SECURING APPLIANCE S ON A PEDESTAL TO THE FLOOR Use the designated holes to secure the unit to the floor SECURING APPLIANCE S WITH LEGS TO THE FLOOR 1 The bracket engages around the square extrusion of the leveling bolt inserted into the leg 2 Once appliance is leveled position the bracket and attach to the floor using the appropriate hardware ...

Page 7: ...to the room through appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built or masonry chimney If you are using a factory built chimney it must comply with UL 103 or CSA B365 standard therefore it must be a Type HT 2100 F It must be installed according to the manufacturer s s...

Page 8: ... as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blocka...

Page 9: ...tor Use this as a pass through for a minimum 24 gauge single wall steel chimney connector Keep solid pak section concentric with and spaced 1 25 4 mm off the chimney connector by way of sheet metal support plates at both ends of chimney section Cover opening with and support chimney section on both sides with 24 gage minimum sheet metal supports See that the supports are fastened securely to wall ...

Page 10: ...m rain or snow also accelerates the drying time A good indicator of if the wood is ready to burn is to check the piece ends If cracks are radiating in all directions from the center then the wood should be dry enough to burn If your wood sizzles in the fire even though the surface is dry it may not be fully cured and should be seasoned longer Do not burn manufactured logs made of wax impregnated s...

Page 11: ...lling on it and close the door If the piece ignites within 90 seconds from the time it was placed into the stove your wood is correctly dried If ignition takes longer your wood is damp If your wood hisses and water or vapor escapes at the ends of the piece your wood is soaked or freshly cut Do not use this wood in your stove Large amounts of creosote could be deposited in your chimney creating pot...

Page 12: ...at going up the chimney as lost energy Therefore efficiency calculated using the lower heating value of wood will be higher than the efficiency calculated using the higher heating value In the United States all woodstove efficiencies should be calculated using the higher heating value The best way to achieve optimum efficiencies is to learn the burning characteristic of this appliance and burn wel...

Page 13: ... these gases is somewhere between 275 F and 500 F Below these temperatures the build up of creosote is promoted Above 500 F heat is wasted since a too large quantity is lost into the atmosphere TO PREVENT CREOSOTE BUILD UP Always burn dry wood This allows clean burns and higher chimney temperatures therefore less creosote deposit Leave the air control fully open for about 5 min every time you relo...

Page 14: ...ves are sold The glass should be washed only when cold PAINT Only clean your stove with a dry soft cloth that will not harm the paint finish If the paint becomes scratched or damaged it is possible to give your wood stove a brand new look by repainting it with a 1200 F heat resistant paint For this purpose simply scrub the surface to be repainted with fine sandpaper clean it properly and apply thi...

Page 15: ...W2020E BP 1 7 29068 Pedestal AW2020E BP 1 8 29065 Pedestal Front AW2020E BP 1 9 610922 Pedestal Weldment AW2020E BP 1 10 610925 Ashpan Housing AW2020E BL 1 11 40566 Cast Iron Leg AW2020E BL 4 12 29071 Ash Pan 1 13 891137 Brushed Nickel Handle 1 14 610927 Damper Slide Weld 1 15 610066 Slide Retainer Weld 1 16 86954 Damper Rod 1 17 891331 Spring Handle Brushed Nickel 1 18 891495 Hearth Trim 18 1 19 ...

Page 16: ...86953 Secondary Air Tube Ø1 8 2 4 86952 Secondary Air Tube Ø11 64 1 5 29039 Brick Retainer left 1 6 29040 Brick Retainer right 1 7 40561 Ash Plug 1 8 24103A Half Pumice Firebrick 4 1 2 X 4 1 2 2 9 891414A Half Firebrick 2 10 89066A Pumice Firebrick 4 1 2 X 9 14 Key Part No Description Qty 1 83788 Socket Head Screw 1 2 893062 Roller Sleeve 1 3 891167 Spring Handle 1 4 893164 Door Handle 1 5 891373 ...

Page 17: ...Notes ...

Page 18: ...Notes ...

Page 19: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date _____________________ Engineer Name ________________________________ License No ________...

Page 20: ...ECHANGE VEUILLEZ CONSERVER CE GUIDE DANS UN ENDROIT SÛR À DES FINS DE RÉFÉRENCE LORSQUE VOUS NOUS ÉCRIVEZ VEUILLEZ INDIQUER LE NUMÉRO COMPLET DU MODÈLE QUI FIGURE SUR LA PLAQUE SIGNALÉTIQUE DE L APPAREIL DE CHAUFFAGE LORSQUE VOUS COMMANDEZ DES PIÈCES DE RECHANGE VEUILLEZ TOUJOURS FOURNIR LES RENSEIGNEMENTS SUIVANTS TELS QUE MONTRÉS DANS CETTE NOMENCLATURE 1 The PART NUMBER LE NUMÉRO DE PIÈCE______...

Page 21: ...___________________________ Service de 07 Date _____________________ Nom de l ingénieur ____________________________ N de licence _________________________________ Compagnie ___________________________________ N de téléphone _______________________________ Poêle Inspecté Cheminée balayée Articles Remplacé _____________________________ Service de 02 Date _____________________ Nom de l ingénieur ___...

Page 22: ...e d air secondaire ø11 64 1 5 29039 retenue de brique gauche 1 6 29040 retenue de brique droite 1 7 40561 bouchon de cendre 1 8 24103A brique réfractaire demi pierre ponce 4 1 2 x 4 1 2 2 9 891414A demi brique réfractaire 2 10 89066A brique réfractaire ponce 4 1 2 x 9 14 8 9 5 4 3 6 7 11 2 1 10 Clé Partie Description Qté 1 83788 Vis à tête creuse 1 2 893062 Manchon à rouleau 1 3 891167 Poignée de ...

Page 23: ... po 1 3 25845 Déflecteur d air 1 4 891492 Ensemble ventilateur B36 1 5 26060 Bouclier arrière 1 6 610926 Cendrier arrière AW2020E BP 1 7 29068 Piédestal AW2020E BP 1 8 29065 Front de piédestal AW2020E BP 1 9 610922 Soudure sur piédestal AW2020E BP 1 10 610925 Logement en cendrier AW2020E BL 1 11 40566 Pied en fonte AW2020E BL 4 12 29071 Cendrier 1 13 891137 Poignée en nickel brossé 1 14 610927 Sou...

Page 24: ... la pièce endommagée par une neuve Effectuez la procédure en sens inverse après remplacement Lors du remplacement de la vitre vous devrez changer le joint de la vitre pour vous assurer qu elle soit bien étanche Ne lavez jamais la vitre avec un produit qui pourrait la rayer Utilisez un produit spécialisé disponible dans les magasins qui vendent les poêles à bois La vitre doit être nettoyée uniqueme...

Page 25: ...nt tous les registres Attendez que le feu s éteigne et que l appareil de chauffage refroidisse puis inspectez les dommages de la cheminée S il n y aucun dommage effectuez le nettoyage de la cheminée pour garantir qu il n y ait pas de dépôts de créosote qui soient restés dans la cheminée ÉLIMINATION DES CENDRES Les cendres devront être éliminées du poêle plusieurs fois par semaine ou quand la couch...

Page 26: ...ux de combustion après qu un bon feu est établi un taux de combustion plus bas peut être la meilleure option pour un chauffage efficace Un taux de combustion plus bas ralentit la sortie du flux de chaleur utilisable hors de la maison par la cheminée et il consume également moins de bois FUMÉE VISIBLE La quantité visible de fumée produite peut être une méthode efficace pour déterminer comment le pr...

Page 27: ...résent manuel contrevient aux réglementations fédérales LES PREMIERS FEUX La peinture fraîche de votre poêle a besoin d être cuite pour préserver sa qualité Une fois que le combustible est correctement allumé faites uniquement brûler de petits feux dans votre poêle lors des quatre premières heures de fonctionnement N ouvrez jamais la commande d air plus que nécessaire afin d obtenir une vitesse de...

Page 28: ... brûlées à la fois pour vous assurer que la température ne dépasse jamais 246 C 475 F sur un thermomètre magnétique pour une installation sur des tuyaux de poêle à paroi simple ou 482 C 900 F sur sonde thermométrique pour l installation sur un tuyau de poêle à double paroi Le thermomètre doit être placé à environ 18 457 mm au dessus du poêle Des températures plus élevées peuvent entraîner une surc...

Page 29: ...avec une partie de cheminée Solid Pak fabriquée en usine agréée d au moins 12 304 mm de diamètre intérieur avec une isolation de 1 25 4 mm ou plus et un raccord de cheminée de 8 de diamètre intérieur de 2 pouces 51 mm plus grand que celui de 6 152 4 mm Utilisez celle ci comme passage pour un raccord de cheminée métallique pour paroi unique de calibre 24 minimum Maintenez la section concentrique so...

Page 30: ... un bon tirage CHEMINÉE EN MAÇONNERIE Assurez vous qu une cheminée en maçonnerie réponde aux standards minimum de l Association nationale de protection contre les incendies NFPA en la faisant inspecter par un professionnel Assurez vous qu il n y ait pas de fissures de mortiers perdus ou d autres signes de détérioration et de blocage Faites nettoyer la cheminée avant d installer et de faire fonctio...

Page 31: ... votre cheminée doivent avoir le même diamètre que la sortie du poêle 6 po Si ce n est pas le cas nous vous recommandons de contacter votre vendeur afin de vous assurer qu il n y aura aucun problème de tirage Le tuyau de poêle doit être fabriqué dans un acier aluminisé ou laminé à froid d une épaisseur minimale de 0 021 po ou 0 53 mm Il est strictement interdit d utiliser un acier galvanisé Votre ...

Page 32: ...explosions se produisent qu il y ait ou non des matières combustibles 2 Les appareils à foyer existants au sein du domicile tels que des cheminées ou d autres appareils de chauffage émettent des odeurs ne fonctionnent pas correctement émettent des fumées lorsqu ils sont ouverts ou des contre explosions se produisent qu il y ait ou non des matières combustibles 3 Ouvrir légèrement une fenêtre lors ...

Page 33: ...oins 18 pouces d espace libre entre le tuyau et le plafond Il doit également y avoir une protection du sol sous la conduite horizontale qui s étend de 2 po au delà de chaque côté du conduit de cheminée La hauteur entre le sol et le plafond doit être d au moins 7 2 13 m dans tous les cas Ne placez aucune matière combustible à moins de 4 1 2 m de l avant de l unité Le dégagement entre le tuyau de ca...

Page 34: ... SIMILAIRES POUR DÉMARRER OU RAVIVER UN FEU DANS CE POÊLE MAINTENEZ TOUS CES LIQUIDES ÉLOIGNÉS DU POÊLE EN CAS D INCENDIE DE CHEMINÉE FERMEZ COMPLÈTEMENT LA COMMANDE D AIR AFIN DE PRIVER LE FEU D OXYGÈNE APPELEZ LES POMPIERS NE CONNECTEZ PAS LE POÊLE À UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR UNE SOURCE D AIR FRAIS DANS LA PIÈCE OU L ESPACE CHAUFFÉ DEVRA ÊTRE FOURNIE SI NÉCESSAIRE POSITIONNER L...

Page 35: ...100 F 650 C Hauteur minimale de la cheminée 12 3 7 m Longueur maximale des bûches 21 po 533 5 mm Dimensions Générales Profondeur x Largeur x Hauteur AW2020E BL 21 po x 27 po x 31 4 po 534 mm x 686 mm x 798 mm AW2020E BP 21 po x 29 4 x 31 25 po 534 mm x 737 mm x 794 mm Chambre de combustion Largeur x Profondeur 22 3 4 po X 11 78 po 578 mm X 300 mm Volume Pieds cubes 1 6 cubic feet Ouverture de la p...

Page 36: ...tion de cet appareil de chauffage Contactez les responsables locaux de l immeuble ou des services d incendie pour connaître les permis restrictions et exigences d installation dans votre région MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouvel appareil de chauffage Le non respect de ces instructions peut entraîner des dommages matériels des blessur...