ULTRA-CUT 400 XT
Manual 0-5275
APPENDIX
A-65
If the fault is E239 that means it is currently active, that is, currently detected as being too high. If it’s L239 that
means the voltage too high previously but it is not too high now. Applying START will clear the fault unless
it becomes active again.
The voltage that triggers an AC Voltage High fault is above 550V for 480VAC line; above 470V for a 380, 400 or
415V nominal line; above 270V for a 208 or 230VAC line.
Possible causes:
• Incoming voltage is or was too high.
• Bad connection at J62 or J27
• Bad connection at J61 jumper
• System Bias board defective
• CCM defective.
Troubleshooting:
1. If the fault is L239 applying START will clear the fault unless it becomes active again. An occasional prob-
lem may be due to incoming voltage swells (voltage increases lasting from ½ cycle to as much as a minute).
Usually, if the plasma is at fault the problem will be present all the time.
2. It is unlikely that an open connection on the J61 jumper would result in a 239 fault, more likely to be a Volt-
age Mismatch fault. However, if it’s intermittent at exactly the right time, perhaps not fully plugged in, it
could possibly show up as 239. Check J61.
3. If the incoming voltage is OK and the problem persists it may be the System Bias board, the CCM or the
connection between J62 and J27.
a. If the incoming voltage is OK and D4 is on or signal “AC V HIGH b” on J62-6 is “high” (about 24VDC,
relative to TP1 or J62-8 ) the System Bias board is defective.
b. If D4 is not on and the signal “AC V HIGH b” on J62-6 is “low” (about 10-14VDC, relative to TP1 or J62-
8) then System Bias is OK and problem is in the CCM.
c. If J62-6 is near zero volts there may be bad connection between J62-6 and J27-6 or J62-7 and J27-6.
240
AC Voltage Low
Refer to the first paragraph for code 239 for explanation of what should happen when the input voltage is correct.
Voltage Low -- If the System Bias board determines AC voltage is too low it lights a red LED, D14, ACV LOW,
and sets the signal “AC V LOW b” on J62-10 to a “high”, about 24VDC (normal for a “low” here is 10-14VDC).
Power is not removed from T1 as low voltage won’t damage anything, However, if it’s too low for too long,
some things like contactors, AC solenoids, the gas controls or TSC 3000 may stop working. A low voltage, if it’s
low enough, may also light D3, the red Missing Phase LED. This does not indicate the phase is actually missing.
The voltage that triggers an AC Voltage Low fault is 380V for a 480VAC nominal line; 300V for a 380, 400 or
415VAC nominal line; 175V for a 208 or 230 VAC line.
Possible cause:
• Incoming voltage is now, or was previously, too low.
o Power distribution wires or power cord too small for the load.
o Loose or high resistance connection somewhere in the power distribution or power cord connection.
• Bad connection at J62 on the System Bias board or J27 on the CCM.
• Bad connection at J61 jumper on the System Bias board.
• System Bias board defective.
• CCM defective.
Summary of Contents for Ultra-Cut 300 XT
Page 6: ...This Page Intentionally Blank...
Page 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Page 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Page 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Page 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Page 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Page 213: ......