ULTRA-CUT 400 XT
Manual 0-5275
OPERATION
4-9
4. Current Control
Adjusts the output current of the power supply.
High Precision
Plasma Cutting System
PREFLOW
H
2
O
MIST
PLASMA
SHIELD
PRESSURE
PLASMA
POWER SUPPLY
GAS
FLOW
High Precision
Plasma Cutting System
ENABLE
DISABLE
GAS
MODE
RUN
SET PREFLOW
SET PLASMA
& SHIELD
TEST
O2 - AIR
O2 - O2
H35 -N
2
F5 - N
2
AIR - AIR
N
2 -
H
2
O
N
2 -
N
2
9
9
Art # A-04767_AC
GCM
2010
AMPERAGE
SET-UP
AMPERAGE
SET-UP
5. Plasma Power Supply Enable / Disable Switch
The DISABLE position removes input power from the Power Supply inverters, disables the coolant pump and fan, the pilot
contactor & HF and removes AC power from the gas control solenoids shutting off all gas flow. When the switch is returned
to the ENABLE position an automatic gas purge is started and then the system is returned to normal operation under control
of the CNC device.
6. PREFLOW Control Knob and Pressure Gauge
Used to set preflow gas pressure and flow. MODE switch must be in SET PREFLOW position.
7. PLASMA and SHIELD Control Knobs, Pressure Gauges and Flow Meter
Used to set plasma and shield gas pressures and flows. Mode switch must be in SET PLASMA & SHIELD position.
8. Gas Pressure Flow Switch
At lower flow rates shield gas pressure is first set per the cut charts then the flow is set using the flow meter with the GAS
switch set in the FLOW position. Some torch parts require higher flow rates that exceed the capacity of the flow meter. In
that case, Gas switch is set in the PRESSURE position and the regulator and gauge is used to set pressure per the cut charts
when no “Ball” setting is shown.
9. H
2
O Mist Control Knob and Flow Meter
Used to set water flow rate. MODE switch must be in SET PLASMA & SHIELD position. GAS selection switch must be in
N
2
-H
2
O position.
NOTE!
Water mist is not used in all applications.
Summary of Contents for Ultra-Cut 300 XT
Page 6: ...This Page Intentionally Blank...
Page 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Page 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Page 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Page 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Page 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Page 213: ......