ULTRA-CUT 400 XT
4-20
OPERATION
Manual 0-5275
CCM Status Code
Code
Message
Remedy / Comments
Group 7 -- Options
701
Isolation Contactor Fault
1 Torch isolation contactor W5 appears closed when expected to be
open. Contacts may fused or, W5 could be energized, 24 VAC on it's
coil, when it should not be due to faulty Relay PCB.
702
Contact Start consumable fault
Prior to 1 torch preflow there should be continuity from the electrode,
through the start cartridge, to the tip. Failure may be due to worn or
missing consumable or Start Cartridge. Inspect, clean or replace.
703
Contact Start detection circuit
fault
In the 1 Torch module K201 should energize when W5 does. Either it
failed to energize or the pressure switch PS2 is failed closed.
704
Contact Start pressure fault
Pressure switch PS2 detects less than 35 PSI. Normal pressure is 75-85
PSI. No air connected to the 1 Torch module inlet or it's too low pres-
sure; if using optional single stage filter the element may need cleaning
or replacement, refer to maintance section. ;1 Torch pressure regulator
set too low; 1 torch module solenoid SOL4 has failed; Relay PCB does
not apply 24 VAC to SOL4.
705
Contact Start Cartridge fault
Air pressure should seperate the Start Cartridge from the tip to initiate
pilot. Failure may be stuck or damaged cartridge or consumables. Clean
or replace. Or no DC output from inverters, front panel DC LED does not
come on.
Summary of Contents for Ultra-Cut 300 XT
Page 6: ...This Page Intentionally Blank...
Page 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Page 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Page 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Page 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Page 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Page 213: ......