ULTRA-CUT 400 XT
A-54
APPENDIX
Manual 0-5275
104
Transfer Lost
Arc transferred to metal for at least 50 ms. then went out.
Causes for 104 code:
• Cut demand set much lower than recommended for torch parts, i.e. 100A consumables in torch but cut
current set for 30 or 50A (or zero). Current may be too low to keep arc on.
• Torch standoff too high for cutting process being used.
• Plasma gas flow too low due to a leak somewhere between the plasma regulator or the DPC 3000 and the
torch. Check for leaks.
• Coolant flow goes too low while cutting causing the unit to shut the arc off. This normally should set 402
fault but for reasons currently unknown sometimes the fault is 104.
o One cause of low flow is defective O-ring in the torch check valve assembly. Replacing the O-ring is the
solution.
• Remote analog current control switches set wrong.
o If remote analog current control is being used, SW8-2 (CCM CPU PCB) is on and SW11 (CCM I/O
PCB) is set to “A” (down) position, but no analog voltage connected to TB1-10 or J15-30 (CNC cable)
then cut demand will be zero, pilot will be weak, depending on torch height it may still transfer but
will immediately go out.
o If remote analog current control is not being used but either SW11 is set to the down position or SW8-2
is on also results in zero cut demand.
o If system is Auto-Cut XT, current control is an analog voltage from the GCM 1000 XT or the AC 200
XT front panel pot. The current control setting will be shown on the front panel 4 digit display. SW8-
2 should be off and SW11 set to up position. With pot at max, check for 3.3V on CCM I/O PCB TP9
(TP1 common). While turning the pot toward minimum TP9 voltage should vary linearly to zero V.
Art # 12309
2
1
3
SW11
TP9
TP1 GND
0-3.3VDC
GND
Divide
by 3.
From Remote
analog Current
Control
CCM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J26
GND
+10.0V
R1
10K
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J55
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J56
GCM 1000 XT
(125)
(126)
(127)
Auto-Cut XT Power Supply
(AC 300 XT)
R1
10K
AC 200 XT
105
Not Used. This is one of the reserved codes from the earlier product.
106
Pilot Timeout, no Transfer
Pilot time is limited to either 0.085 seconds (85 ms.) with CCM SW8-1 off (default for pierce starting) or 3 seconds
with SW8-1 on (used for cutting over holes, expanded metal, etc.). Arc must transfer before pilot time ends.
Code 106 is set if no arc transfer (current in work lead) was sensed before pilot timed out. If the unit does not
detect pilot current the arc starter will operate up to 15 seconds then set the 102 code. If you are getting 106 there
is pilot current somewhere. If it’s not visible perhaps it’s inside the consumables or following some other part.
Causes for 106 code:
No Pilot Visible:
• Pilot inside the consumables
Summary of Contents for Ultra-Cut 300 XT
Page 6: ...This Page Intentionally Blank...
Page 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Page 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Page 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Page 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Page 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Page 213: ......