ULTRA-CUT 400 XT
5-2
MAINTENANCE
Manual 0-5275
5.03 Coolant Replacement Procedure
Replace coolant as follows:
1. Disconnect the system from main input power.
2. Remove the two right side panels.
3. Locate the coupling in the coolant line that comes from the bottom of the coolant tank, #1 in the following illustration.
Disconnect the coolant line at this fitting and drain the coolant into a disposable container of sufficient size. Remember
you will be draining more than the contents of the coolant reservoir.
4. Once coolant is draining, disconnect the gray hose coupling #2 in the illustration below. Allow excess coolant to drain,
then apply a maximum of 5psi to clear the lines.
!
CAUTION
Applying more than 5 psi air pressure to the cooling system will result in damage.
Extra caution must be used when performing this task.
2
1
Art # A11689
5. Reconnect those two fittings and then remove the filter bowl from the canister at the rear of the power supply. Pour this
remaining coolant into the container and replace the filter bowl.
NOTE!
If you also need to replace the coolant still in the leads, disconnect the leads
from the power supply and manually drain them.
6. Fill the tank with fresh coolant until the right level is reached checking for leaks.
7. Turn system on, let it run for a few minutes and check coolant level, refill as needed. Refer to Section 3:22 Complet the
Installation on the procedure for this.
8. Install the side panels.
Summary of Contents for Ultra-Cut 300 XT
Page 6: ...This Page Intentionally Blank...
Page 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Page 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Page 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Page 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Page 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Page 213: ......