Troubleshooting:
1. First recycle power to see if the fault is still there. It may now show up as one of the 225-230 codes which
will indicate which inverter.
2. Determine when the code shows up. If it is EMI it may not happen every time but if, when it happens, it is
always at the beginning of piloting, it may be EMI interference. Check the system ground cables and if an
AC200XT check the torch shield connection to the unit rear panel.
3. If it happens intermittently during cutting or idling it might be an intermittent ribbon cable. This code does
not say which inverter section so you have to check each ribbon cable for proper connection on each end. It’s
highly unlikely for a ribbon cable to be intermittent but if you have more than 2 sections try disconnecting
one section at a time and cut at lower current. See if you find one that causes the problem and if so replace
that ribbon cable.
Group 3 codes relate to the GAS Controls Status and Communication Protocol
Also refer to GCM 2010 Status Codes at the end of this Group 3 codes section.
301
Gas Control Communication Fault
No signal detected over the fiber-optic link from the gas control. In the case where there are additional devices
other than Gas Control connected to the CANBUS this code would indicate the Gas Control is having commu-
nication problems while the other CANBUS devices are OK. We don’t currently have any other devices on the
CANBUS so it is more likely that code 501 will be what is set. In any case troubleshooting is the same as for 501.
Possible cause:
• Most likely cause is dirty or defective fiber-optic cable or connector.
• Cable to GCM 2010, DMC or DPC not connected or broken.
• Defective control board or power supply in the Gas Control
• Defective CCM
Troubleshooting:
1. Check that the fiber-optic cable is fully plugged in to both sockets. Clean the cable ends with a soft cloth
and blow out the sockets with air.
2. Check gas control cables. If any of the gas control cables are not connected there will be no communication
as there will be no power to the control. This may show up as a 301 or 501 code. Also if the cable is broken
or defective such that the gas control is not enabled it may have power but in the case of the DMC or DPC
its fault light will blink error 101 while the CCM will only detect that there is no communication and it will
show 301 or possibly 501.
302
Gas Control communications reply fault
Communication has been established but Gas Control did not reply to a request from the CCM in the time al-
lowed. Likely cause is Fiber-optic problems (see code 501) or if problem persists defective Gas Control main PCB.
303
Gas Pressure fault
Gas pressure faults only show up when you try to start the torch, not during purging or setting flows .
With the Auto-Cut 200 XT and the Auto-Cut 300 XT (GCM 1000 XT), the gas pressure sensor is only on the
plasma gas and is in series with Run/Set switch. A 303 code here indicates either plasma gas missing or very
low pressure, less than 50 PSI, or RUN/SET switch is in SET position.
Starting with GCM2010 revision AG we measure inlet pressure of both plasma and shield gas at the inlet of
the gas selection manifold. If pressure is either too low or too high it sets 303 code. Earlier revision should not
display 303 code. GCM2010 will display which gas is the problem and its actual pressure. The pressure at the
point where it is measured should be in the range of 100-135 PSI. Exception is for shield gas if the Gas switch
is set to Pressure then the min pressure can be 85 PSI.
Summary of Contents for Ultra-Cut 300 XT
Page 6: ...This Page Intentionally Blank...
Page 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Page 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Page 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Page 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Page 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Page 213: ......