ULTRA-CUT 400 XT
A-62
APPENDIX
Manual 0-5275
2. If the report is current too low (which included no current) check the connections.
3. The ribbon cable for the first inverter section (IM#1A) must connect to that section only but if there are 2
additional sections, unit is 200A or greater, swap the ribbon cable going into those sections.
a. If it now reports a different section as bad, the one whose cable was moved, then the original section was
bad.
b. If it still reports the original section the ribbon cable or the CCM is bad (unlikely).
c. Swap both ends of the ribbon cable with one next to it. If still reports the original section then the problem
is with the CCM if not then it’s the ribbon cable.
4. If it’s the first inverter section or it’s a 100A unit so there’s no other inverter to swap cables with, replace the
inverter.
Additional hint: Inverter control PCBs have a green LED, D24, PWM ON, that lights when that section is enabled
and has a demand signal. The LED brightness is relative to the output so may be very dim if output is low. If
that LED doesn’t light may indicate a defective inverter (control board).
224
Inverter 1 not found.
There must be an inverter connected in the 1st section, 1A, to be able to pilot. During the power up sequence,
before power is connected to the inverters, the CCM does a continuity test to see if its section 1A ribbon cable
(J31 on CCM) is connected.
Causes & troubleshooting:
• As this is just a continuity test it is very unlikely to be a bad inverter. Most likely a poor connection or
defective ribbon cable.
o Check ribbon cable connections at both ends of INV1A to CCM J31 (1A) cable. Make sure it is plugged
into J31, the top connector, on the CCM.
o Plug a different inverter cable into J31, doesn’t matter which one for this test as long as it’s plugged
into an inverter on the other end. If still gives 224, “Inverter 1 not found” fault, it’s a bad CCM. Oth-
erwise it’s the ribbon cable.
225-230 Inverter Revision and CCM incompatible.
If sometime in the future we should make a change to the inverter making it incompatible with older CCM we
have included a hardware key that would change to indicate this. During the power up sequence, before power
is connected to the inverters, the CCM does a continuity test to determine what is the hardware key configura-
tion. The key uses 3 lines of the CCM to inverter ribbon cable which are named IS_ID_A, IS_ID_B, IS_ID_C (on
pins 12, 13 & 14) and checks for continuity to a 4th line OUTCOM (pin 9). The test consists of applying voltage
to OUTCOM and looking for that voltage coming back on the 3 ID pins. The present configuration has all 3
lines connected to OUTCOM so all 3 should be high.
To get the 225-230 code now when we don’t have any incompatible revisions would most likely be a bad con-
nection in the ribbon cable between the CCM and the inverter or a defective CCM (unlikely).
• On the inverter section swap the ribbon cable with that of a different inverter section. If fault remains
unchanged, still calls out the original inverter section, the problem is with either ribbon cable or CCM.
• On the inverter end put the ribbon cables back in their original positions. Now swap suspect ribbon
cable with another one on the CCM. If the fault now moves to a different section it’s the ribbon cable. If
it remains with the original section the problem is the CCM.
231-236 Inverter VAC Mismatch.
Different inverter modules are manufactured for 480VAC, 380-415VAC & 208-230VAC operation voltages. There
is a key, called inverter ID, read through the inverter’s ribbon cable, to identify which voltage range the inverter
is designed for. The unit itself is wired differently for the different input voltages and part of that includes a
jumper at J61 on the System Bias board that indicates to the System Bias board what voltage the unit is wired
to accept.
Summary of Contents for Ultra-Cut 300 XT
Page 6: ...This Page Intentionally Blank...
Page 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Page 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Page 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Page 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Page 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Page 213: ......