SECTION 4: OPERATION
4.01 Power Supply Control Panel
Art # A-11541_AB
AC Indicator
Temp Indicator
Gas Indicator
DC Indicator
A/
Status Indicator
A/
AC Power Lamp
Indicates unit has passed the input power tests and AC power is being supplied to the inverter modules via the input contactor
when the ON/OFF switch is in ON position.
TEMP Lamp:
Normally OFF. Lamp will come ON when the internal temperature sensors detect temperatures above normal
limits. Let the unit cool before continuing operation.
GAS Lamp:
Flashing during start up gas purge/pump priming, then steady whenever gas is flowing. Indicates adequate gas
pressure and coolant flow for operation.
DC Lamp:
Indicates the power supply is generating output DC voltage.
A/
Status Indicator:
Shows CCM code version on start up followed by the Current Control setting and system status.
Refer to Section 4.07 and Status Code Section for details.
Rear Panel AC Power Lamp
Indicates AC power is present inside the unit
Summary of Contents for Ultra-Cut 300 XT
Page 6: ...This Page Intentionally Blank...
Page 10: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 15: ...ULTRA CUT 400 XT Manual 0 5275 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 88: ...ULTRA CUT 400 XT OPERATION Manual 0 5275 This Page Intentionally Blank...
Page 106: ...ULTRA CUT 400 XT REPLACEMENT PARTS Manual 0 5275 This Page Intentionally Blank...
Page 114: ...ULTRA CUT 400 XT TORCH INFORMATION Manual 0 5275 This Page Intentionally Blank...
Page 139: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 25 Display PCB Test Points TP1GND TP2 5VDC TP3 24VDC...
Page 148: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 150: ...ULTRA CUT 400 XT APPENDIX Manual 0 5275 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 201: ...ULTRA CUT 400 XT Manual 0 5275 APPENDIX A 87 This Page Intentionally Blank...
Page 213: ......