B-1
Themis Computer
B
Rack-Mount Slide Installation
An
optional
set of two rack-mount slides (left side and right side) is available for all
RES systems, and should be ordered at the time of purchase. The RES-XR4-1U
chassis contains nine threaded screw holes on each side to accommodate M4x6mm
size screws (included with the rack-mount slide kit); steel slides require four mount-
ing holes, and aluminum slides require three mounting holes (see
Figure B-1
).
Dimensions of the screw-hole patterns on the sides of the RES-XR4-1U chassis for
installing rack-mount slides are shown in
Figure B-1
. The required holes for a spe-
cific steel or aluminum slide will have to be measured before installation.
Figure B-1.
Screw Locations for Rack-Mount Slides
440.8
339.2
250.6
202.4
149.1
85.6
37.6
Front
0
424.9
24.9
Screw Hole Size = 4mm
Legend
Mounting
Bracket
Note:
All dimensions are given in millimeters (mm), and measured from the baseline “0” of the drawing
Appendix
Summary of Contents for RES-XR4-1U
Page 16: ...xiv Themis Computer RES XR4 1U Betriebshandbuch Version 1 5...
Page 30: ...xxviii Themis Computer RES XR4 1U Installation Manual Version 1 5...
Page 34: ...RES XR4 1U Installation Manual Version 1 5 xxxii Themis Computer...
Page 67: ...1 33 Themis Computer 1 Overview and Specifications RES System...
Page 68: ...1 34 Themis Computer RES XR4 1U Installation Manual Version 1 5...
Page 146: ...3 46 Themis Computer RES XR4 1U Installation Manual Version 1 5...
Page 152: ...A 6 Themis Computer RES XR4 1U Installation Manual Version 1 5...
Page 156: ...Themis Computer RES XR4 1U Installation Manual Version 1 5 B 4...
Page 184: ...D 8 Themis Computer RES XR4 1U Installation Manual Version 1 5...
Page 196: ...RES XR4 1U Installation Manual Version 1 5 8 Themis Computer...