1-17
Themis Computer
Overview and Specifications
Specifications
1.3.3
Environmental
1.3.3.1 Shock
The RES-12DCX is designed to survive an elevated shock environment. All struc-
tural components are welded together, enabling the system to survive a maximum
3-axis shock load of 25G at 20-msec duration.
1.3.3.2 Electrostatic Discharge
The RES-12DCX is designed to tolerate electrostatic pulses up to 15 kilovolts (KV)
with no impact on system operation.
1.3.3.3 Noise Level
Typical noise levels emitted by the RES-12DCX are outlined in
Table 1-5
. The chas-
sis is installed with four 38-mm fans contained side-by-side in a single fan assembly.
Table 1-5.
Typical Noise Levels of the RES-12DCX
Measured at:
1 Meter
2 Meters
Front
66.24 dB
57.57 dB
Rear
61.53 dB
57.93 dB