11-1-5. GP-IB connection
The following chart shows the wiring for when the GP-1B is used to connect IF-70GU to a PC:
Operation of the GP-IB has been verified by using a GP-IB board manufactured by National Instruments.
A sample program is available on our website.
●
No operation problems occurred when using a GP-
EE488 specifications. For details
about programming GP-IB, see the instruction man
ng used, or the manual for the
sample program.
●
LF (0x0A) and EOI are applied to set the delimiter.
Be sure to output the delimiter after outputting the command
Note that CR (0x0D) will be ignored. Be careful not to enter
●
At least half of the devices to which the GP-IB is connected m
n.
Turn on the power of all the devices.
●
Two addresses are required for the address setting of the PS-A
C
address.
Make sure to specify "1" as the system address for the PS-A
●
The GP-IB complies with the IEEE488-1978 specifications.
Interface actions are SH1, AH1, T6, TE0, L3, LE0, SR0, RL1
11-1-6. USB connection
The following chart shows the wiring for when the USB is used to co
IB that satisfies the IE
ual for the interface bei
s and parameters.
the wrong letters.
ust be powered o
power supply unit: the system address and P
unit connected to the PC.
, PP0, DC0, DT0, and C0.
nnect IF-70GU to a PC:
PS-A units support USB2.0 full speed. The USB ports on a PC can be used.
●
The dedicated device driver and API provided by us need to be installed and configured on your PC. Visit our
website to download the device driver and API.
◆
For details about the required PC environment and operation procedures, see the API instruction manual.
It does not support USBTMC.
●
This device driver does not support the suspension or sleep modes from the PC side.
●
The environment in which a USB is used is extremely susceptible to external noise, which may cause the USB
to malfunction. Install the USB in manner that minimizes the effect of noise on the communication pathway,
and make sure to implement countermeasures against noise.
●
When a PS-A series unit is used with a USB, two addresses are required for the address setting: the system
address and PC address.
Make sure to specify "1" as the system address for the PS-A unit connected to the PC.
●