![TEXIO PS-A Series Instruction Manual Download Page 45](http://html1.mh-extra.com/html/texio/ps-a-series/ps-a-series_instruction-manual_1097528045.webp)
6-4-2. Setting the output when the power is turned on
When the power is turned on, the PS-A power supply unit can turn the output on, without needing to push the OUTPUT
key.
Operation procedure
1. Turn on the power switch while pressing and
holding the MENU key.
Release the MENU KEY when the panel is lit.
The MENU key is then lit in green, and the
ESC/KEY LOCK key and the ENTER/MEM key
start blinking green.
The function name is displayed in the voltage
indicator, and the function setting is displayed
(blinking) in the current indicator.
2. Repeatedly press the MENU key until "Pout" is
displayed in the voltage indicator.
3. Turning the rotary encoder displays the following in
the current indicator. Select the desired setting.
OUTPUT OFF
OUTPUT ON
4. Press the green-blinking ENTER/MEM key to enter
the setting.
After the setting is entered, the current indicator
stops blinking, remains lit for a short while, and
then starts blinking again.
5. Press the green-blinking ESC/KEY LOCK key to
exit. The message shown in the figure on the left
appears. Normal operation of the unit is then
available.
Turn the power switch off and then back on to
display the entered voltage and current.
By specifying the above setting, the unit will start with the output on when the
power is turned on. However, this may destroy loads if the wrong voltage or
current have been set.
Be sure to confirm the set voltage and current values before turning the power off.
If a standard board or IF-70PS has been installed, this setting can only be
performed when the external output is on.
35
35