![TEXIO PS-A Series Instruction Manual Download Page 71](http://html1.mh-extra.com/html/texio/ps-a-series/ps-a-series_instruction-manual_1097528071.webp)
9-1-2. Wiring an analog signal to the standard board
See the figure below for details about how to wire an analog signal to the standard board, and how to select the logic and
different functions.
Fig. 9-1. Standard Board Connector and Dip Switch
While the unit is in operation, connect the applicable outer contact, voltage, and resistance to the negative output of
the unit.
Note that the outer contact, voltage, and resistance must be float-mounted.
The photo-coupler, which is used to output alarms and the status of CV mode and CC mode, must be used at a current
of 5mA or lower when it is on, and at a voltage of 10V or lower when it is off.
Function
Connection
terminal
SW1 Action
OFF
Close circuit: Main relay off
Open circuit: Main relay on
Main relay on/off
Pin No.3 to 4
of CN1
Pin No.1
of
SW1
ON
Close circuit: Main relay on
Open circuit: Main relay off
OFF
Close circuit: Output off
Open circuit: Output on
Output on/off
Pin No.1 to 2
of CN1
Pin No.2
of
SW1
ON
Close circuit: Output on
Open circuit: Output off
OFF
Photo-coupler on when status is alarm
Photo-coupler off when status is normal
Alarm output
Pin No.5 to 6
of CN1
Pin No.3
of
SW1
ON
Photo-coupler off when status is alarm
Photo-coupler on when status is normal
61