Description
|
7-2
Engineered to Endure
Interface for Tx Redundant (1+1) Systems
The Tx 1+1 interface module is a passive unit. The module divides the frequency shift
keying (FSK), 10 MHz reference and L-band signals, as well as routes the Ethernet
connection to the IBUCs through an Ethernet switch. It supports various interface
connectors and includes a bank of LEDs for visual indication of alarm conditions.
The user interface is one of the following: via Web browser through the included
Embedded Web pages, TCP/IP through a Telnet session, UDP through SNMP, RS485,
Hand-held Terminal, RS232, as well as FSK link to both IBUCs.The system provides
automatic switching between IBUCs in the event of failure. The IBUCs communicate
with each other to monitor status and execute switching logic. A software command is
available in the IBUC to enable the unit designated as the Master to clone itself to the
Slave to match the unit’s configuration. Monitor and control (M&C) functions are
available through the interface module via Hand-held Terminal, RS232, RS485, TCP/
IP, and FSK. Two Form-C relays are provided for alarms (one for the A: side IBUC
and on for the B: side IBUC). In the redundant system, remote M&C by using RS485
and TSP/IP is available via the interface module, which eliminates the need to run two
separate M&C cables to the IBUCs. In the case of FSK, M&C is available on the IFL
cable and no additional cables are required. M&C commands for redundant systems
are present in the IBUC software. For more information about ASCII commands, see
Appendix F, ASCII Command/Response Structure
.
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...