![Terrasat IBUC 3 Operation Manual Download Page 154](http://html.mh-extra.com/html/terrasat/ibuc-3/ibuc-3_operation-manual_1089882154.webp)
C-22
|
IBUC
3
,
IBUC
3
G
Operations Manual: Embedded Web Pages
Engineered to Endure
• Other IBUC Public IP Address
Sets the public IP address of the partner IBUC. This option is used to enable the
dual display of the embedded web pages for each IBUC unit on the same browser.
• Warm Standby Mode
Sets the power amplifier into standby mode (a lower power-consumption mode
that is designed to reduce energy usage when not in use). Depending on the model,
the unit will only consume 20 watts to 100 watts. When enabled, the standby unit
will have its output power turned Off until the switch to it occurs. Warm standby
mode is available only when the A: side unit is the primary (or protected) unit and
the B: side unit is the standby unit.
Options include:
•
Enable
•
Disable
Note:
When warm standby mode is enabled, the redundancy mode automatically
switches to non-reverting. If warm standby mode is later disabled, the redundancy
mode remains non-reverting until you manually change it.
Note:
When the A: side unit has been repaired, user intervention is required to place it
back in redundancy mode.
Event Log Tab
Use this tab to view the event history of the IBUC
3
and IBUC
3
G
. When a fault
occurs, an entry is added to the event log. Entries are timestamped to determine the
order in which the events occurred. These events can be used to help determine cause
during system troubleshooting.
A total of 1000 events are stored by the IBUC. In
, the events recorded
consist of a timestamp and text string. The string can describe an alarm or
informational text. Events are displayed oldest to newest in multiples of 25. The
Next
button displays the next screen of events while the
Back
button displays the previous
screen. To clear the alarm history, click
Clear
.
Figure C.13
Event Log Tab
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...