![Terrasat IBUC 3 Operation Manual Download Page 105](http://html.mh-extra.com/html/terrasat/ibuc-3/ibuc-3_operation-manual_1089882105.webp)
System Alignment and Operation
|
7-15
Engineered to Endure
Test Equipment
Terrasat recommends the equipment or its equivalent listed in
for
installation and system alignment.
Ensure that the Tx output power is disabled to prevent accidental transmission
interference with adjacent satellites or transponders before attempting to align or
performing any other operation involving the ODU. Before attempting any system
change, carefully evaluate the possible effects of the transmitted signal.
Setting the Tx Frequencies
All transmit and receive frequencies are set by using the modem. For a direct
connection to an L-band modem, follow the manufacturer’s instructions on setting the
transmit and receive frequencies.
Tx Power Alignment
Transmit L-band Input Adjustment with Modem or Converter
To set the power level of the modulator output:
1. Use a spectrum analyzer to measure the power level of the L-band signal at the
output of the coaxial cable that connects to the Tx 1+1 interface module at J2 (Tx
L-band).
Table 7.7
Recommended Test Equipment
Equipment
Type
Spectrum Analyzer
Agilent HP8563E
Digital Voltmeter
Fluke 8050
Waveguide-to-coaxial Adapter
C-band or Ku-band
RF cables
With calibrated insertion loss up to 15 GHz
40 dB attenuator
High power to match HPA output
Assortment of cables, connectors and adapters
(calibrated up to 15 GHz)
!
WARNING
DC power might be present on the cable. Terrasat recommends the use
of a DC block.
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...