![Terrasat IBUC 3 Operation Manual Download Page 65](http://html.mh-extra.com/html/terrasat/ibuc-3/ibuc-3_operation-manual_1089882065.webp)
Start-up Checklist
|
4-5
Engineered to Endure
Example
: After observing the unit, you determine that the output level operates
consistently at 32 dBm. Although the threshold range is 21 dB, that range is too
wide for everyday use. Instead consider setting the output thresholds at ±3 dB; this
would make the high level threshold 35 dBm and the low level threshold 29 dBm.
Note:
You will receive an error message if the input level exceeds the threshold range.
4. Verify your settings against the readings on the Sensors Page, as shown on
Appendix C, Embedded Web Pages
.
Configuring Alarm States
The IBUC offers flexibility with the levels of alarms produced when user
-
specified
thresholds are exceeded.
1. Consider which alarms to configure.
contains the default
alarm configuration. Each alarm that is user configurable can be set as a major
event, a minor event, or be disabled.
2. Establish a connection with the IBUC
3
or IBUC
3
G
by using the steps provided
in
Appendix C, Embedded Web Pages
.
3. Navigate to the Alarm Configuration tab shown on
.
4. Use the drop-down menus to mark an alarm as a major event, a minor event, or to
disable it.
5. Click
Save Settings
when you have completed your inputs to ensure that your
settings are saved. If you do not click
Save Settings
, your changes will not be
implemented.
Configuring ALC/AGC
The IBUC
3
and IBUC
3
G
offer two methods of ensuring consistent signal levels:
automatic level control (ALC) and automatic gain control (AGC).
ALC
When enabled, the Automatic Level Control (ALC) circuitry in the IBUC monitors
output levels and adjusts the gain to maintain a consistent output for input signal
variations. If a signal level is consistently below the predetermined target level, the
ALC will cause the gain to be increased until the target level is reached. If a signal
level exceeds the target level, the ALC will decrease the gain.
To enable ALC,
1. Establish a connection with the IBUC
3
or IBUC
3
G
by using the steps provided
in
Appendix C, Embedded Web Pages
, and open the Tx Configuration Tab.
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...