Screen Shots
|
C-21
Engineered to Endure
From this page you can configure the following parameters:
• Set IBUC Location
Specifies the physical location of each IBUC on the switch. In a redundant system,
there must be an A: side IBUC and an B: side IBUC (not two A: side IBUCs nor
two B: side IBUCs). Options include:
•
A
•
B
• Set Online IBUC
Specifies which IBUC is online. Options include:
•
A
•
B
• Redundancy Mode
Sets the redundancy switching mode of operation. When configured for reverting,
the units can switch between each other multiple times when a fault occurs unless
both units are faulted. In non-reverting mode, when the A: side unit faults, a switch
to the B: side unit will occur. However, once operation has switched to the B: side
unit no additional switches will occur without user intervention. This item can be
changed only from the unit designated as Online (Master). Options include:
•
Reverting
•
Non-reverting
• Redundancy Switching Type
Sets the switching type. Options include
•
Automatic
•
Manual
Note:
In Automatic Mode, if the standby unit is faulty, the online IBUC will not switch
to the standby unit. However, you can force this switch when in Manual Mode.
• Auto Clone Settings
Sets the cloning configuration of a redundant pair. When enabled, the settings that
are common to both units are copied from the online IBUC to the standby IBUC.
Options include:
•
Enable
•
Disable
• Other IBUC IP Address
Sets the IP address used to determine the location of the partner IBUC. This
address is used by the internal Ethernet Switch of the interface box (see
) to enable communication between IBUCs.
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...