Operations Manual: Installation
Engineered to Endure
(American Wire Gauge) stranded copper wire to ground the IBUC
3
or IBUC
3
G
to
the antenna frame and to the lightning protection ground rod. For higher power units
with an external power supply, Terrasat recommends using an isolation filter to reduce
power line interference.
Mounting Considerations
Optional mounting brackets are available to aid mounting on most antennas. The ODU
must be mounted such that:
• The IBUC has sufficient support to minimize the effects of antenna sway in strong
winds.
• The fan intake and exhausts are free from any obstructions.
• The heat fins have air movement across them.
Throughout installation and during any polarization, azimuth or elevation adjustment,
ensure that cables and waveguide are not crimped or pinched. Ensure that there is
adequate slack in the cable.
Power Requirements
For rated power levels of 16 watts and below for Ku
-
band the power for the IBUC can
come either from the IFL supplied from the Terrasat indoor unit (IDU) equipped with
a 200 watts power supply or from a satellite modem equipped with a suitable power
supply. DC power for these lower power IBUCs can also be supplied directly through
the external power connector (J3) by using the Terrasat 250 watts external power
supply. Refer to the part number label (shown in
) to determine
voltage requirements. Ensure that 24 VDC input voltage is from 20 VDC to 28 VDC
and that the 48 VDC input is from 37 VDC to 60 VDC.
Outdoor Power Supply
Terrasat offers four models of outdoor power supplies. DC
-
powered IBUCs with a
rated power level higher than 16 watts Ku
-
band require a separate power supply. Units
that get their power from the earth (or telecom) station do not require an external
power supply.
lists the four outdoor power supply models and applications
!
WARNING
Installation and connection to the line power supply must be made in
compliance with applicable wiring codes and regulations.
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...