![Terrasat IBUC 3 Operation Manual Download Page 212](http://html.mh-extra.com/html/terrasat/ibuc-3/ibuc-3_operation-manual_1089882212.webp)
F-44
|
IBUC
3
,
IBUC
3
G
Operations Manual: ASCII Command/Response Structure
Engineered to Endure
Redundancy Commands
This section contains information about various redundancy commands. The
commands are applicable to Tx 1+1 and Rx1+1 systems, unless noted otherwise.
Definitions of error responses are found in
BAE
Note:
Applies only to Tx 1+1 Systems
Description: Displays the redundancy configuration of the IBUC
3
or IBUC
3
G
.
Parameters:
<Redundancy>
0 - Redundancy disabled
1 - Redundancy enabled
<Position>
Master Position
Slave Position
<Clone>
Clone Enabled
Clone Disabled
Q
Query: BAE
Response: BAE=<Redundancy>, <Position>, <Clone>
Error Response: 7, 19
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...