![Terrasat IBUC 3 Operation Manual Download Page 107](http://html.mh-extra.com/html/terrasat/ibuc-3/ibuc-3_operation-manual_1089882107.webp)
Final Checks
|
7-17
Engineered to Endure
M&C Setup
Tx Redundant System
Default Values
A: SIDE IBUC
RS485 Data Rate is 9600 baud
RS485/FSK Mode is 1 (Legacy Binary mode)
Default IP address is 192.168.1.21
Other (standby) BUC IP address is 192.168.1.22
IP gateway address is 192.168.1.1
B: SIDE IBUC
RS485 Data Rate is 9600 baud
RS485/FSK Mode is 1 (Legacy Binary mode)
Default IP address is 192.168.1.22
Other (standby) BUC IP address is 192.168.1.21
IP gateway address is 192.168.1.1
Note:
RS485/FSK Mode 1 is the default setting to enable compatible modems to use the
“Legacy Binary” mode to communicate with the IBUC.
General
You can communicate with the redundant system via any of the following five
interfaces: TCP/IP, RS232, RS485, hand-held terminal (HHT), and FSK link. FSK is
delivered to the interface module from the modem via the J2 connector. The FSK link
uses FSK signals between the IBUC and modem that are multiplexed on the IFL
coaxial cable.
Note:
Use only the J8, J9, or J10 connectors when attempting to communicate with the
IBUC
3
.
• The J8 connector (labeled User Interface – Ethernet) carries TCP/IP.
• The 19-pin J9 connector (labeled User Interface) carries RS232, RS485, the Hand-
held terminal, TCP/IP, and Form-C alarms.
• The J10 connector (labeled Aux Ethernet) carries TCP/IP.
TCP/IP
You can communicate with the IBUC via TCP/IP through Telnet (ASCII) or the
onboard Web server (HTTP). The IBUC uses a static IP addressing structure and does
not support DHCP. The IBUC 1+1 system is factory configured as follows:
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...