Menu Options
|
D-5
Engineered to Endure
Alarm
Tx Thresholds
Interface
S
ECTION
D
ESCRIPTION
View Tx Alarms
Displays current transmitter alarms
View Misc Alarms
Displays current miscellaneous alarms
View Log
Displays the unit alarm log
Clear Log
Clears the unit alarm log
Suppress Faults
Displays or sets whether alarms configured for suppression are
suppressed
Simulate Fault
Displays or sets a major transmitter alarm (used for troubleshooting)
Configure Alarms
Displays or sets whether individual alarms cause a major/minor/no alarm
and if the alarm is suppressible
High Temperature
Shutdown
Displays or sets the high temperature shutdown setting of the unit
View Statistics
Displays the latest unit statistic history entries
Clear Statistics
Clears the unit statistic history entries
Statistics Interval
Displays or sets the data collection period for statistics
S
ECTION
D
ESCRIPTION
Input Level High
Displays or sets the input power high threshold
Input Level Low
Displays or sets the input power low threshold
Output Level High
Displays or sets the output power high threshold
Output Level Low
Displays or sets the output power low threshold
S
ECTION
D
ESCRIPTION
IP Address
Displays or sets the IP address of the unit
IP Subnet Mask
Displays or sets the subnet mask of the unit
IP Gateway
Displays or sets the IP gateway of the unit
Web Refresh Rate
Displays or sets the rate at which the Embedded Web Pages will request
updates
RS485/FSK Address
Displays or sets the address used for both the RS485 and FSK interfaces
RS485 Baud Rate
Displays or sets the RS485 Baud Rate
RS485/FSK Delay
Displays or sets the amount of time the unit delays sending a response to
a command
RS485/FSK Protocol
Displays or sets whether the unit communicates with ASCII or Legacy
Binary protocols on both RS485 and FSK interfaces
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...