Operations Manual: Transmit Redundant Systems
Engineered to Endure
M&C Functions
The Tx and Rx redundant systems are designed to provide an interface for user
configuration and control of the systems. In the Tx system, the IBUCs monitor &
status can initiate switching when required. The Online/Master unit always clones it
self to the Offline/Slave unit when cloning is enabled, ensuring that switching between
units can occur as soon as possible. M&C features are available via the interface
module enabling a single point of control for both IBUCs. Commands and alarms
unique to the redundant system are built in to the IBUC M&C software.
The interface module includes an Ethernet hub to enable users to monitor and control
both IBUCs in TCP/IP with a single Ethernet connection and cable.
For remote operation, the redundant systems are equipped with a Monitor and Control
function. The M&C function includes an FSK modem interface, an RS232 interface,
an RS485 interface, a hand-held terminal, an Ethernet interface, multifunction LEDs,
and two alarm relay closures (Form-C): one for the A: side IBUC and one for the B:
side IBUC.
User Interfaces
•
Tx Systems:
A bank of LEDs provide visual indications of Tx 1+1 status.
•
Hand-held Terminal (HHT):
An optional item that can be used to access the Tx
Systems for local M&C via ports J4 (the A: side IBUC) and J6 (the B: side IBUC).
The HHT has a 4-row x 20-column display with four function keys (F1-F4), a
numeric keypad (0-9), and YES, NO, BKSP (backspace), SPACE, and ENTER
keys. Initiate the HHT session by typing “. . . .” (4 dots), followed by the password.
The default password is 1234.
The HHT menu consists of a main menu with multiple submenus. Access the main
menus by pressing the left/right arrows (F2, F3) and the submenus by pressing the
up/down arrow keys (F1, F4). Select a submenu item by pressing the ENTER key.
To maneuver back to the previous screen, press the BKSP (backspace) key. Some
screens (for example, INFO) only display information whereas other screens
require user input. User input fields are reflected by the corresponding digit and a
colon (such as 0:) as shown in the HHT Menu Tree on
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...