General Requirements
|
3-5
Engineered to Endure
for each. Power supplies have an autoranging AC front end that works with both
115 VAC and 230 VAC.
Note:
The IBUC is configured at the factory to be floating. Ensure that the correct polarity is
applied to any unit.
Indoor Power Supply
Terrasat offers a 1000 watts indoor power supply unit (PSUI) which provides 48 VDC
power. The 1000 watts PSUI can power C
-
band and X
-
band units through 125 watts,
Ku
-
band units through 80 watts, and Ka
-
band units through 40 watts. Each indoor
PSUI is packaged in a rack
-
mountable chassis which occupies one rack unit (1.75 in.)
of space. The indoor PSUI is shipped with a mating connector for DC power and a
power cord for AC mains.
Note:
AC transients and surges can cause data transmission errors and loss of
synchronization in the modem and/or the ODU. Take proper precautions to ensure
uninterrupted service.
Grounding
Terrasat recommends the following grounding and lightning protection:
• Cable Shielding
Shield currents can be eliminated with proper techniques. A grounding strap at the
end of the coaxial and data cables should be connected to the ground lug at the
antenna base with #4 gauge copper wire. This provides a path of least resistance
prior to entering the equipment.
Table 3.2
Terrasat Outdoor Power Supplies
Model
Output Power
Application
PSUI-948-0250S-4
250 W
• C-band up to 25 W
• X-band up to 25 W
• Ku-band up to 16 W
• Ka-band up to 16 W
PSUI-948-600-4
600 W
• C-band up to 80 W
• X-band up to 80 W
• Ku-band up to 50 W
• Ka-band up to 40 W
PSUI-948-1000-4
1000 W
• C-band 100 W to 125 W
• X-band 100 W to 125 W
• Ku-band 60 W to 80 W
PSUI-948-600-4
1200 W
• C-band 150 W to 200 W
• X-band 150 W to 175 W
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...