Common Errors
|
4-7
Engineered to Endure
To re-enable transmission, remove the Pin N connection to Pin F. Transmission will
now resume. For more information about the M&C interface connector, see
.
Alarm Input
When the unit is operating as part of the redundant IBUC system, the redundant
configuration is sensed automatically. In redundant systems, Pin N functions as an
alarm input where the alarm output of the A: side IBUC is connected to the alarm
input of the B: side IBUC and vice versa.
For more information about the M&C interface connector, see
Common Errors
LED is Red
A red LED indicates only that a fault (or alarm) has occurred and does not necessarily
indicate that transmission has stopped. A flashing red light indicates a minor alarm and
a solid red light indicates a major alarm. You can communicate with the IBUC to
determine what is causing the fault, and then clear the fault condition.
1. Establish a connection with the IBUC
3
or IBUC
3
G
by using the steps provided
in
Appendix C, Embedded Web Pages
.
2. View the Alarm Status Tab (shown on
) to determine the current alarm.
You can also check the Sensor Tab (shown on
) to determine which
reading caused the alarm, and then compare the readings with the threshold levels.
If necessary, adjust the threshold level(s).
When the fault is cleared, the LED should be flashing green.
No Power to the IBUC
3
or IBUC
3
G
If the Power LED is off or not turning on at all, the IBUC is probably not receiving
power.
Restore power to the IBUC by
• If the IBUC is powered by the modem, verifying that the modem is working
properly.
• Checking that the modem is receiving power (that is, the modem power cord is
plugged in) and that DC power to the IBUC is enabled.
• Checking that all cable connections are solid.
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...