![Terrasat IBUC 3 Operation Manual Download Page 100](http://html.mh-extra.com/html/terrasat/ibuc-3/ibuc-3_operation-manual_1089882100.webp)
7-10
|
IBUC
3
,
IBUC
3
G
Operations Manual: Transmit Redundant Systems
Engineered to Endure
Transmit Output J5, J7, J8 and J10
The J5, J7, J8 and J10 connectors are shielded Ethernet Connectors used to enable
remote monitoring and control of the Tx 1+1 System operating parameters. Pin
assignments are listed in
.
User interface J9
The User Interface connector is a 19-pin circular connector used to enable remote
monitoring and control of the Tx 1+1 System operating parameters. The J9 connector
enables use of RS485, the Hand-held Terminal (HHT), RS232, and alarms. Pin
assignments are shown in
. If the user interface port of the Tx 1+1 interface
module is going to be used, the cable should be a shielded multi-conductor cable with
at least two each twisted pairs. The twisted pairs used for TCP/IP must have an
impedance of 100 ohms. For cable drawings, see
Specifications and Reference Drawings
. An assembled IP cable is available from
Terrasat.
Note:
Customers who order a Hand-held terminal (HHT) will receive two cables: one is
wired specifically for the A: side IBUC, and the other is wired specifically for the B:
side IBUC. The cables are marked for usage.
Table 7.4
Pin Assignments for M&C Interface connectors J5, J7, J8, and J10
Pin
Function
1
TCP/IP TX(+)
2
TCP/IP TX(-)
3
TCP/IP RX(+)
4
NOT USED
5
NOT USED
6
TCP/IP RX(-)
7
NOT USED
8
NOT USED
Table 7.5
Pin Assignments for M&C Interface Connector J9
Pin
Function
A
RS485(+)
B
RS485(-)
C
HAND-HELD TERMINAL POWER(+)
D
A: HAND-HELD TERMINAL, RS232 RXD
E
A: HAND-HELD TERMINAL, RS232 TXD
F
HAND-HELD TERMINAL, RS232, RS485 COMMON
G
TCP/IP TX(+)
H
TCP/IP TX(-)
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...