TRASMETTITORE ELETTRONICO DI LIVELLO, PRESSIONE E VUOTO
ELECTRONIC LEVEL, PRESSURE AND VACUUM TRANSMITTER
Sistema Gestione Qualità, Ambiente e Sicurezza
Quality Management System, Environment and Safety
MNT7N01
Rev. 19.07
Issued by
:
MZ
Figura /
Figure
6 – connessione / connection T76
DIN 175301 PG9/PG13 3+1 poli
1 = V+ alimentazione, 2 = V- comune,
= massa collegata
alla custodia
DIN 175301 PG9/PG13 3+1 poles
1= V+ supply, 2 = V- common,
= earth connected to housing
Figura /
Figure
7 - connessione / connection T76
Connettore M12
1 = V+ alimentazione, 2 = V- comune, 3 non collegato,
= massa collegata alla custodia
M12 Connector
1= V+ supply, 2 = V- common, 3 not connected,
= earth connected to housing
A
limentazione
L’elettronica della serie T7 necessita di una tensione di
alimentazione tra 12 e 30Vcc.
Il segnale di uscita dello strumento è standard 4÷20mA in
tecnica a 2 fili, con protocollo HART
®
- FSK.
La tensione di alimentazione, in base al carico richiesto, è
determinata nel seguente modo:
V
cc
(min) = 0.0215 x R (carico) + 12 [Vcc]
Dal grafico di Figura /
operativa di funzionamento dello strumento.
Power Supply
The T7 series electronics needs a supply voltage
between 10 and 30Vdc.
The output signal is 2 wires 4 ÷ 20mA, with HART
protocol - FSK.
Power supply, depending on the requested load is
according to the below equation:
V
cc
(min) = 0.0215 x R (load) + 12 [Vcc]
It is possible to see the Operating Area of the
instrument in the below