5. Cut the cable ties from the main wire harness /
brush motor connection and disconnect the main
wire harness from the brush motors.
6. Disconnect all solution supply hoses from the scrub
head.
7. Remove the cotter pin and clevis pin securing the
actuator to the head suspension spring bracket.
8. Remove the hex screws and fl at washers securing
the head lift bracket to the scrub head.
9. Reconnect the battery cable to the machine.
10. Turn on the machine, allow the scrub head to
completely raise, and turn off the machine.
11. Disconnect the battery cable from the machine.
12. Remove the batteries from the machine.
FOR SAFETY: When servicing machine, avoid
contact with battery acid, keep all metal objects off
batteries, and use a hoist or adequate assistance
when lifting batteries.
13. Lift the machine from the scrub head.
14. Proceed to REMOVE / INSTALL THE LOWER
ORBITAL HEAD ISOLATORS if replacing the lower
isolators.
15. Reinstall the removed scrub head / install the new
scrub head onto the machine in the reverse order
of removal.