106
T500 9015504 01-2018
SERVICE
6. Remove the front scrub head cover from the
machine.
7. Cut the cable ties from the main wire harness /
brush motor connection and disconnect the main
wire harness from the brush motors.
8. Disconnect all solution supply hoses from the scrub
head.
9. Remove the cotter pin and clevis pin securing the
actuator to the head suspension spring bracket.
10. Remove the cotter pins and clevis pins securing
the head lift arms to the scrub head assembly.
11. Remove the clevis pin and cotter pin securing the
scrub head pivot to the head guide bracket.
12. Reinstall the removed scrub head / install the new
scrub head onto the machine in the reverse order
of removal.
13. If removed scrub head was replaced with an
orbital scrub head, reconfi gure the machine for the
orbital scrub head. See RECONFIGURING THE
MACHINE AFTER NEW HARDWARE / OPTION
INSTALLATION in this section of the manual.